Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 56 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Using the Reader Setup Wizard
This procedure outlines how to use the setup wizard to help setting up a new Reader.
NOTE: If the configuration alignment icon is shown in the banner , both primary and secondary sides
of the reader are configured with the same settings; i.e. there is no need to repeat the Wizard on the
Secondary side of the reader. Note that you will need to configure a small subset of unique settings (see
Configuration Alignment, page 69).
1. Start the Wizard from the Primary side of the reader, from the Dashboard page, via the Wizard button.
Enter the Site Name. Avoid adding any Primary or Secondary side designation within the site name, as the reader
automatically adds a “-pri” or “-sec” suffix in logs and in the banner. The same site name will be applied to the
secondary side.
Select the site type. This sets an initial voting time, which is used to determine when the reader generates a passage
(VOTE) report to the lane controller.
The next wizard page is used to select which tag protocols are enabled. Select all required tag protocols (click on
the + icon to add items). You can enable reader sync here as well by adding a "Sync" item. Any power (Tx Attn) or