Reader Status panel
Field
Status
Description
Other Side CTM Presence
Is the other side of the CTM present or absent in the chassis.
Other Side Config
Compare
Communication Down (peer CTM is not running so
configuration state is unknown)
Same (peer CTM configuration is identical to this CTM’s
configuration)
Different (peer CTM configuration is different that this CTM’s
configuration)
Front-panel switch
position
Auto; Primary; Secondary
Auto, Primary (switch set to Primary side), Secondary (switch
set to Secondary side).
For a redundant system, the switch would normally be set to
Auto
CFM Status
Present
Indicates normal status
Not Detected
Indicates a problem; call Kapsch Service
Frame Seq. Config.
Indicates whether or not the last attempted frame sequence
configuration contains errors. If an error is indicated, review
the Tag Protocol configuration, and review the event/trouble
logs for more detailed information.
Super Frame Time (μs)
Reader timing information (frame sequence length) In
microseconds
CPU Load
High (above 50%)
Extreme (above 80%)
Uptime
Number of seconds since power up.