Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader 2.4 Maintenance Instructions
Confidential UM 360467-110 Revision: B Page 213 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
CAUTION:
Improper modification of configuration parameters may adversely
affect system operation. It is the system integrator’s responsibility
to load configuration parameters relevant to the specific operating
environment.
1. From the Save / Load page, click the button to locate a previoulsy saved configuration file.
2. In the confirmation dialog click "Yes" load the configuration settings from the file.
3. Settings are applied immediately. A reboot is not required.
Resetting the Reader configuration to the factory default
Certain field service tests use the factory default configuration. This procedure outlines how to restore the
factory default settings.
CAUTION:
The factory default configuration should not be restored on a
running Reader. Save the current Reader configuration before
resetting the Reader configuration to the factory default, in
case you want to recover previous settings.
1. Click on the Save / Load button on the Configure panel of the reader home page.
Click the Reset Parameters to Default Values button.
Result: All configuration values, except for the Reader network settings, site name, and user account settings,
revert to the factory defaults. A reboot is not required.
User Administration
User administration permissions are needed when a new user account needs to be created, when an account
needs to be changed, or deleted. The user can be given any combination of the following permission attributes:
• Admin User
• Manage Software (permission to update / change running version of reader software)
• Manage Logs (permission to download or delete logs)
• Change Configuration (permission to change reader settings)
Prerequisites: Accessing the Reader web interface, page 42. Admin User permissions.