Ensure that LC communications is configured, that is, the appropriate Ethernet and Serial selections are made in
the Destinations field.
For serial connections, review these settings:
Send Serial Heartbeat should only be enabled if the Lane Controller is able to respond to hearbeat messages. LC
Retry Timeout
Navigate to the General page, and review the Switchover panel:
Toggle Switchover on serial LC link down and/or Switchover on Ethernet LC link down, as required.
Note: When setting the LC Retry Timeout, consider the baud rate used to communicate with the LC and the
processing speed of the LC to avoid false failure reports.
If Switchover on Serial Link Down is enabled, from the LC Serial panel on the Lane Controller page, enter a
time, in milliseconds, in the LC Retry Timeout field. If an LC does not respond within this time, the Reader will
consider serial communications to the LC to be down and will trigger a switchover if the SPM redundancy mode
switch is in AUTO.
If Switchover on Ethernet LC Link Down is enabled, enter a time, in milliseconds, in the LC Ethernet TCP-Socket
Timeout text box. If an LC does not respond within this time, the Reader will consider Ethernet communications to
the LC to be down and could trigger a switchover if the SPM redundancy mode switch is in AUTO.
Configuring the Reader to switch over when the Ethernet IR link is down
Prerequisites: Inter-Reader Voting has been configured
1. From the home page, click on General button.
In the Switchover panel, toggle Switchover on Inter-Reader link down