Kapsch TrafficCom
Replacing a PSM fuse
WARNING:
INSTALLING A FUSE OF THE WRONG TYPE OR RATING MAY
CAUSE A FIRE. INSTALL A TIME LAG FUSE RATED FOR 10A.
1. Set the PSM power switch to the off position.
Disconnect the AC power cord.
Using a flat-tipped screwdriver, rotate the fuse holder counter-clockwise 180 degrees. Slide out the fuse holder as
shown in Figure 7-1.
Figure 7-1: PSM fuse and fuse holder
Rotate the fuse holder clockwise to allow the old fuse to fall free of the fuse holder.
Place the new fuse in the fuse holder then slide the fuse holder into the PSM.
Using a flat-tipped screwdriver, rotate the fuse holder 180 degrees to secure the fuse holder in the PSM.
PSM
fuse holder
fuse