CFM replacement
WARNING:
THE MODULES MAY HAVE SHARP EDGES. HANDLE THE
MODULES CAREFULLY. WHENEVER POSSIBLE, USE A MODULE
EXTRACTION TOOL TO REMOVE A MODULE.
Removing a CFM
1. If possible, save the reader configuration to a file (see Saving the Reader configuration, page 212).
Remove the CTM on the side of the faulty CFM (see CTM, page 202).
While pushing on plastic clips, pull CFM straight out from DSM.
Installing a CFM
1. Push CFM straight into connector on DSM until an audible click is heard.
Install the CTM removed in step 0 (see CTM, page 202).
Load the configuration file saved in step 1 to the new CFM (see Loading a reader configuration, page 212), or locate
and upload the latest saved Reader configuration.