Multi-Protocol Reader 2.4 Maintenance Instructions
Confidential UM 360467-110 Revision: B Page 191 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Disconnect each Reader one at a time from the sync hub until the fault clears then reconnect each Reader in the
order of removal until the fault reappears. Service each faulty Reader.
Sync board Failure Indicator for incomplete cable connections
The CTM SYNC LED will flash steadily red if there is no activity on the Rx port on the terminal block of the SPM
(R+ and R- on the connector). If both transmit and receive connections are cut off from the sync hub the
indicator will flash red. If only the transmit connection is disconnected and there are other Readers in the
synchronization network, the CTM SYNC LED stays green.