Kapsch TrafficCom
Troubleshooting tree: MRFM-S not working
START
Symptom:
MRFM-S LED is OFF
MRFM-S
DATA LED
OFF?
Contact Kapsch Service for
assistance
Replace the MRFM-S
CTM ACTIVE
LED ON?
MRFM-S
DATA LED solid
green?
Verify antenna is
undamaged.
Verify all cable connections
from antenna to RF
module.
Verify RF channels are set
to Active.
Perform Sync
Troubleshooting
No
YesNo
Yes
Yes
No
Replace the CTM
Yes
No
MRFM-S is
functional
MRFM-S DATA
LED solid green?
MRFM-S is
functional