Troubleshooting tree: LPM Serial Port communications not working
Start
Symptom:
Status page shows LC Serial Link is down
• Verify serial cable connections from
the reader to the Lane Controller
pass a continuity test for open
circuit, high impedance, or short
circuit conditions.
• Verify LC serial communication
settings are configured correctly
LC Serial link
status displays
Enabled?
LC Serial link is
functional
Test the LPM
board serial COM
port(s)
LC Serial link is
functional
Replace the CTM
LC Serial link is
functional
Replace the LPM
LC Serial link is
functional
Contact Kapsch Service for
assistance
LC Serial link
status displays
Enabled?
LC Serial link
status displays
Enabled?
LC Serial link
status displays
Enabled?
Yes
No
Yes
No
Yes
No
Yes
No