Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader 2.4 Maintenance Instructions
Confidential UM 360467-110 Revision: B Page 171 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Ensure all the COM Ports selected in step 6 are enabled by the corresponding Port State switch.
Select the Baud Rate, Data Bits, Parity, and Stop Bits to match the LC communication settings.
Example: An example of what your screen may look like after selection.
Refer to the Configuring the Reader to switch over automatically when an LC link is down procedure on page
208 to configure the Reader to switch over when the connection from the LPM to the LC is down.
Reader connections to the LC and Inter-Reader via Ethernet
Reader IP addresses
Each Ethernet port in an IR or LC network must have a unique IP address. The IP addresses should be set as
required for the site network topology. Default settings are:
Ethernet 1 port: 192.168.1.50
Ethernet 2 port:
192.168.0.50 (primary side)
192.168.0.51 (secondary side)
Setting the reader IP addresses
Prerequisites: Accessing the Reader web interface, page 42. Do not connect both sides of a reader to a
network until each CTM has been given a unique Ethernet 1 IP address.
Note: A secure record of the IP addresses should be maintained to aid network troubleshooting. The
primary and secondary Ethernet 1 IP addresses will be required if requesting remote assistance from
Kapsch Service.
1. From the reader dashboard, select the General page. The network settings are shown in the "Network"
panel.