Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 132 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
Compare Page
Set Configuration
Aligned
On the Compare page:
Click on Keep aligned
with primary side switch.
User with
Change
Configuration
permission
EKOCFG
1
0 - 1
0 – Automatic mirrowing the configuration is
disabled.
1 – Automatic mirrowing the configuration is
enabled.
Configuration
Compare Request
On the Compare page:
Click on button
Anyone
N/A
N/A
N/A
Request configuration compare between Primary
and Secondary sides of the reader.
Save /Load Configuration Page
Save Config
On the Save/Load
Configuration page:
Click the Download
reader configuration
icon to save.
User with
Change
Configuration
permission
N/A
N/A
N/A
Save current Reader configuration into a file.
The file can then be reloaded later or used to
configure other Readers.
Upload Config
On the Save/Load
Configuration page:
Click the Load a
configuration file icon to
load.
User with
Change
Configuration
permission
N/A
N/A
N/A
Load a previously saved reader configuration file
from your device to the reader.
The reader network settings (see General page) and
site name are not changed.