Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
Programming
Timeout (ms)
On the Group panel of
the Channels page:
Enter a time in ms for
each voting group.
User with
Change
Configuration
permission
GRPPTG
300
1-300
This field will be shown when any channel has
Voting time or LPT/FME Voting time equals to 0.
If programming is not successful the reader will keep
trying until the programming timeout value (in
milliseconds) is reaced.
Time Page
Network Time
Protocol
On the Time page:
Set toggle switch to ON
to enable NTP.
User with
Change
Configuration
permission
NTP___
0
0-1
Enables or disables setting the Reader time via an
NTP server
to ensure readers are time synced to a time server.
NTP time offset
warning threshold
(ms)
On the Time page:
With NTP enabled,
Input threshold in
milliseconds.
User with
Change
Configuration
permission
NTPMAX
20
1-100
Specify a maximum threshold (default 20 ms) for the
largest NTP time offset tolerated in the system.
When NTP is enabled, the reader periodically
checks its NTP time offset, and if it is greater than
the threshold, change the NTP status parameter
to one of the Alarm values. An alert is also shown
in the UI banner.
NTP Server 1, 2, 3
and 4
On the Time page:
With NTP enabled,
enter three different
valid NTP server IP
address in the NTP
Server fields.
User with
Change
Configuration
permission
NTP__1
NTP__2
NTP__3
NTP__4
N/A
N/A
Sets the NTP server IP addresses.
Provides the Reader with four NTP servers it can
access to accurately maintain time with other
Readers in an IR network.