Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 129 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
Dynamic Voting
Threshold [%]
On the Dynamic Voting
panel of the Channels
page:
With Dynamic Voting
Control set to Reader,
enter the voting
threshold percentage in
the Dynamic Voting
Threshold field.
User with
Change
Configuration
permission
DVTHSD
20
5-100
Sets the voting threshold percentage
To configure when the average Voting time is
adjusted. The Voting time will only be updated
when the Reader determines the percent change
is larger than the threshold entered here.
Dynamic Voting
Capture Zone Span
Multiplier
On the Dynamic Voting
panel of the Channels
page:
With Dynamic Voting
Control set to Reader,
enter a voting time
multiplier in the Dynamic
Voting Capture Zone
Span Multiplier field.
User with
Change
Configuration
permission
DVCZTM
2
1-5
Sets the Capture Zone Span Time multiplier
Determines when the Reader checks for voting time
updates.
Transponder
Timeout
On the Group panel of
the Channels page:
Enter a time, in seconds,
in the Transponder
Timeout field.
User with
Change
Configuration
permission
GRPTTO
300
1-300
set the transponder timeout time
to set the amount of time an OBU must be out of a
capture zone before communication with the OBU
is reported as a new transaction