Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 128 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
Voting Time (all
other tag types) [ms]
On the Channels panel of
the Channels page:
Type the Voting Time for
all other tag types in the
appropriate fields.
User with
Change
Configuration
permission
VOTETO
100
0-9999
Specifies the time after the initial entry of the
transponder into the capture zone at which a
VOTE report is generated. A value of 0 means no
voting, subject to the Programming Timeout
parameter.
Dynamic Voting
Control
On the Channels panel of
the Channels page, with
Advanced switch ON:
Select Disabled or
Reader from the
Dynamic voting control
drop-down box (LC
Speed and LC Ends are
not supported).
User with
Change
Configuration
permission
DVCTRL
Disabled
Disabled
Reader
LC Speed
LC End
Disabled: reader uses the fixed voting time
Reader: the Reader monitors the average time an
OBU is in the capture zone and uses this time to
determine an appropriate voting time.
LC Speed: not currently supported.
LC End: not currently supported.
To set type of voting control.
Dynamic Voting
Sample Size
On the Dynamic Voting
panel of the Channels
page:
With Dynamic Voting
Control set to Reader,
enter the desired
number of samples.
User with
Change
Configuration
permission
DVSPSZ
20
1-50
Sets the sample size used in the Dynamic Voting
Calculation.
To configure the Dynamic Voting Control calculation.
The number entered here is the number of
previous transactions used when calculating the
average voting time.