Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 118 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
LC Retry Timeout
From the LC Serial panel
on the Lane Controller
page:
Enter a time, in
milliseconds, in the LC
Retry Timeout field.
User with
Change
Configuration
permission
PROTTO
1000
50-1000
Sets the LC retry timeout
to set the time that the Reader waits for LC
confirmation before resending data . (Serial link
only)
Serial Port State
From the LC Serial panel
on the Lane Controller
page:
Select the Serial Port
State check box for the
required LPM COM port.
User with
Change
Configuration
permission
COM_ST
1
0-1
Disabled: LCM COM port disabled
Enabled: LCM COM port enabled to communicate
with LCto enable or disable communications on each
LPM COM port
Baud Rate
From the LC Serial panel
on the Lane Controller
page:
With the Serial Port
State enabled, select the
desired Baud Rate from
the drop-down box.
User with
Change
Configuration
permission
COM_BR
19200
9600
19200
38400
57600
115200
Sets the LPM baud rate for individual COM ports
to configure the LPM baud rate on a port by port