Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 108 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
LC Ethernet
Connection Mode
On the Lane Controller
page:
Select option in
connection mode.
User with
Change
Configuration
permission
LcECnM
Standard
(Legacy)
Standard (Legacy)
TCP - Long Lived
Specifies how the Reader will connect to the Lane
Controller. Select 'Standard (Legacy)' for the
traditional 'Open-Send-Close' TCP Socket paradigm.
Select 'TCP - Long Lived' for long-lived TCP/IP socket
connections with the Lane Controller. Note that
there are message encapsulation, connection
establishment, and protocol changes as well. refer
to ICD 360467-121 for details.
Send Ethernet
Heartbeats
On the Lane Controller
page:
With LC Ethernet
Connection Mode in TCP
- Long Lived,
set Toggle switch to
enable heartbeat.
User with
Change
Configuration
permission
LCHTBT
1
0-1
Used to detect communication problems between
the Reader and the LC.
Disabled: no heartbeat messages are sent to LC.
Enabled: causes the Reader to send heartbeat
messages to the LC.
Ethernet Heartbeat
Interval (sec)
On the Lane Controller
page:
With send heartbeat
messages enabled, enter
interval time in seconds.
User with
Change
Configuration
permission
LCHBTM
2
1-30
Sets the heartbeat message interval,
i.e. how often heartbeat messages are sent from the
Reader to the LC.
Destination
On the LC Destination
panel on the Lane
Controller page:
User with
Change
Configuration
permission
LCDEST
1
0 - 15
Specifies the type of interface (Ethernet, Dual
Ethernet) communication with the lane controller.