Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 107 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
ATA Hold-Off Delay
Enable
From the ATA Advanced
panel of the Tag Protocol
page:
Set toggle switch to ON
to enable delay.
User with
Change
Configuration
permission
ATAHOE
0
0 - 1
Controls whether ATA CW transmission is held off at
the start of the ATA frame for a period of time in
order to provide a sufficient gap in air time from
the end of transmission of the previous timeslot.
ATA Hold-Off Delay
(µs)
From the ATA Advanced
panel of the Tag Protocol
page:
Select hold off delay in
us from drop-down list.
User with
Change
Configuration
permission
ATAHOD
600 us (3)
0 us (0)
-
1400 µs (7)
(in 200 µs steps)
Specifies how long the ATA CW transmission is
delayed from the start of the ATA frame in order
to provide a sufficient gap in air time from the
previous timeslot.
Lane Controller Page
LC Ethernet TCP-
Socket Local Port
On the Lane Controller
page:
Keep the default value if
necessary.
User with
Change
Configuration
permission
LcEtPn
default: 6666
min: 1024
max: 65535
Used to select the local TCP Protocol Port Number
that the Reader will listen on to accept incoming TCP
connections from the Lane Controller.
LC Ethernet TCP-
Socket Timeout (ms)
On the Lane Controller
page:
With at least one RF
Channel configured to
send data to the LC via
Ethernet, type a time in
milliseconds in field.
User with
Change
Configuration
permission
LcEtTo
500
100-5000
Sets the timeout for a response from the LC via the
LC Ethernet network.
To determine if there is an Ethernet communication
problem between the Reader and the LC.