Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 102 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
6B GROUP_SELECT
Mask (base 10)
From the 6B Advanced
panel of the Tag Protocol
page:
With 6B GROUP_SELECT
enabled, input mask.
User with
Change
Configuration
permission
6BMASK
0
0-FF
Specify the 6B GROUP_SELECT mask to use (in base
10, not hex).
6B GROUP_SELECT
Data (Hex)
From the 6B Advanced
panel of the Tag Protocol
page:
With 6B GROUP_SELECT
enabled, input data.
User with
Change
Configuration
permission
6BDATA
0000000000000
000
000000000000000
0
-
FFFFFFFFFFFFFFFF
Specify the 6B GROUP_SELECT Data to use. Please
enter a 16-digit (64-bit) hexadecimal value.
Initial CW Time (µs)
From the 6B Advanced
panel of the Tag Protocol
page:
Select cw time from the
drop-down list.
User with
Change
Configuration
permissions
6BICWT
400 (4)
Off (0)
100 (1) - 1500
(15)
(in 100 µs steps)
Specifies the initial CW time (in µs)
Dual Tag Preamble
From the 6B Advanced
panel of the Tag Protocol
page:
Set toggle switch to ON
to enable
User with
Change
Configuration
permission
6B_DTP
0
0 - 1
Specifies whether or not the Dual Tag Preamble is
transmitted during the ISO 18000-6B frame.
Preamble Type
From the 6B Advanced
panel of the Tag Protocol
page:
Select preamble type
from the drop-down list.
User with
Change
Configuration
permission
6B_PRT
Plaza (0)
Plaza (0)
ORT (1)
Specify the 6B preamble type.