Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 101 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
eATA Page Read
Retry Limit
From the 6B Advanced
panel of the Tag Protocol
page:
Input a numeric value for
retry limit.
User with
Change
Configuration
permission
6B3PRR
3
0-10
When 6B is enabled and eATA data is being
requested, one page at a time, this value
determines, in the event of an eATA page read
error, the maximum number of consecutive retries
that will be attempted when trying to read a given
eATA page.
6B Data Rate (kbps)
From the 6B Advanced
panel of the Tag Protocol
page:
Select data rate from
the drop-down list.
User with
Change
Configuration
permission
6BRATE
40 (1)
31.25 (0)
40 (1)
Specify the 6B Data Rate
Enable 6B
GROUP_SELECT
From the 6B Advanced
panel of the Tag Protocol
page:
Set toggle switch to ON
to enable
User with
Change
Configuration
permission
6BMSKE
0
0-1
Enable this parameter to allow the reader to instruct
the Reader to activate the 6B GROUP_SELECT
function. This allows the Reader to select a subset
of tags from a given tag population.
6B GROUP_SELECT
Address (base 10)
From the 6B Advanced
panel of the Tag Protocol
page:
With 6B GROUP_SELECT
enabled, input select
address.
User with
Change
Configuration
permission
6BADDR
0
0-FF
Specify the 6B GROUP_SELECT address to use (in
base 10, not hex).