Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader 2.4 Operating Instructions
Confidential UM 360467-110 Revision: B Page 98 of 247
© Kapsch TrafficCom Canada Inc. 2021
All information contained herein is proprietary to, and may only be used with express, written permission from, Kapsch TrafficCom Canada Inc.
FILE: UM 360467-110 REV B3 MPR 2.4 CLEAN.DOCX 03/02/2021 1:01
Kapsch TrafficCom
Command
How to execute
Who can
execute
Prmtr.
Name
Default Value
Prmtr.
Range
Purpose of command
TDM Frequency
[MHz]
Title21 Frequency
[MHz]
SeGo Frequency
[MHz]
6B Frequency [MHz]
6C Frequency [MHz]
ATA Frequency
[MHz]
Dummy (CW)
Frequency [MHz]
From the corresponding
protocol Configuration
panel of the Tag Protocol
page, specify the
frequency.
User with
Change
Configuration
permission
IAGFRQ
T21FRQ
SGOFRQ
I6BFRQ
I6CFRQ
ATAFRQ
DUMFRQ
915.75 (15)
915.75 (15)
902.50 (0)
902.50 (0)
902.50 (0)
902.50 (0)
902.50 (0)
902.5 to 903.5
MHz and
910 to 921.5 MHz
Dependent on
specific protocol
See Appendix B
Specifies the protocol frequencies
Frame Sequence
On the Frame Sequence
box of the Tag Protocol
page:
User with
Change
Configuration
permission
N/A
Empty
Empty
TDM
Title21
SeGo
6B
6C
ATA
Dummy_1
Sync_1
Specifies the Frame Sequence Slot
protocol/function.
Used to specify the protocol firing and/or the
Synchronization Sequence of the Reader.