Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360450-210 Revision C Page 134 of 288
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 REV C JANUS MPR2 OPERATOR-MAINTENANCE MANUAL.DOCX 08/17/2015 11:42
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Report Filtering
ATA Tag Report
Filtering/Threshold:
From the LC tab on the
Configuration page,
select the ATA Tag
Report
Filtering/Threshold
checkbox
user with
Advanced
User
permissions
ATAFLT
Disabled
Disabled
Enabled:1Read
Enabled:2Read
Enabled:3Read
Use this option to perform
filtering of ATA tag reports
(Voting, Post Capture)
based on a set handshake
count threshold.
Sets the minimum
number of ATA tag reads
that must occur on any
given channel before a
given tag is processed
and/or reported to the
Lane Controller.
Set
appropriately,
this feature can
help reduce the
incidence of ATA
'Phantom'
reads/reports.
Verify ATA Data
CRC:
From the LC tab on the
Configuration page
user with
Advanced
User
permissions
ATAVDC
Enabled
Disabled
Enabled
If enabled, instructs the
Reader to perform a CRC
validation check on the
received ATA data. If the
incoming data does not
pass the CRC check,
handshake messages,
Note: if enabled, may be
flagged as invalid, or
suppressed entirely.
N/A