Operations and Maintenance Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360450-210 Revision C Page 129 of 288
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 REV C JANUS MPR2 OPERATOR-MAINTENANCE MANUAL.DOCX 08/17/2015 11:42
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Dynamic Voting
Sample Size
From the Channel tab
on the Configuration
page:
With Dynamic Voting
Control set to Reader,
enter the desired
number of samples.
user with
Advanced
User
permissions
DVSPSZ
20
1-50
Sets the sample size used
in the Dynamic Voting
Calculation
to configure the
Dynamic Voting
Control
calculation. The
number entered
here is the
number of
previous
transactions
used when
calculating the
average voting
time
Dynamic Voting
Threshold [%]
From the Channel tab
on the Configuration
page:
With Dynamic Voting
Control set to Reader,
enter the voting
threshold percentage in
the Dynamic Voting
Threshold field.
user with
Advanced
User
permissions
DVTHSD
20
5-100
sets the voting threshold
percentage
to configure
when the
average Voting
time is adjusted.
The Voting time
will only be
updated when
the Reader
determines the
percent change
is larger than the
threshold
entered here