Operations and Maintenance Manual
_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360463-202: A12 (Draft) Page 89 of 291
© Kapsch TrafficCom Canada Inc. 2014
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: MPR2_OPERATIONS_AND_MAINTENANCE-MANUAL_REV A12.DOCX 05/08/2014 11:24
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Test Tags tab
Test Tag Single
Fault Threshold
From the Test Tags tab on the
Configuration page:
Enter a number in the Test Tag
Single Fault Threshold field,
then, press Enter or select a
different tab.
user with
Advanced
User
permissions
SFT___
6
1-99
sets the number of
consecutive test tag faults
before a channel is
considered bad
to continuously
monitor channel
quality and set a
failure threshold
Test Tag
Multiple Fault
Threshold
From the Test Tags tab on the
Configuration page:
Enter a number in the Test Tag
Multiple Fault Threshold field,
then, press Enter or select a
different tab.
user with
Advanced
User
permissions
MFT___
8
1-8
sets the number of bad
channels that trigger a
switchover
to continuously
monitor channel
quality and set a
failure threshold
for triggering a
switchover
Test Tag Period
From the Test Tags tab on the
Configuration page:
Enter a time, in seconds, in the
Test Tag Period field, then,
press Enter or select a different
tab.
user with
Advanced
User
permissions
TTP___
30
10-99
sets the test tag period
to set the
frequency of test
tag checks
Test Tag State
From the Test Tags tab on the
Configuration page:
Enter a time, in seconds, in the
Test Tag Period field, then,
press Enter or select a different
tab.
user with
Advanced
User
permissions
RFTTST
0
0-1
Enable means start
checking for test tags and
switch-over if the Multiple
Fault Threshold has been
reached.
N/A