User's Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360450-210 Revision: A7 Page 20 of 282
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX 10/31/2013 7:56
Kapsch TrafficCom
During firmware activation (typically less than 60 seconds), the Reader will switch over to
the other side to process and report transactions, regardless of the position of the mode
switch on the SPM module. Ensure that the other side is running normally and all lane
controller links are functioning. The Reader will be unable to process or report transactions
if it is unable to switch over to the other side.
During firmware activation (typically less than 60 seconds), a non-redundant Reader is
unable to process or report transactions.
The factory default configuration should not be restored on a running Reader. The factory
firmware may not be appropriate for the specific application. Save the current Reader
configuration before resetting the Reader configuration to the factory default.
On one redundant reader of a synchronization network, the synchronization connection
should be looped back and this reader will declare sync even if it is disconnected from the
other readers
To avoid damaging the RF adaptor cables, ensure they do not protrude to where items on
the back of the cabinet doors can damage or press on them. Use 90-degree SMA adaptors
where required.