Event
Cause
Enabling
Failed Ethernet
Lane Controller Link
The Reader forces a switchover when an
enabled Ethernet link has failed. Usually a
downed link is due to external conditions.
A downed link is detected regardless of
whether OBU transactions are being
generated or not.
Must enable Switchover on
Ethernet LC Link Down from
General tab on
Configuration page
User must set LC Ethernet
TCP-Socket Timeout from LC
tab on the Configuration
page
Failed Inter-Reader
Ethernet Link
The Reader continuously checks the link
status of the IR network and forces a
switchover if it fails.
User must set IRIF Timeout
from Lane Assignment tab
on Configuration page
Reader Software
Update
During activation of a different firmware
version, the Reader switches automatically to
the redundant side if the redundant side is
running and has no switchover conditions
present. If the redundant side is not
functioning, the Reader warns the operator of
potential revenue loss and allows the
operator to either continue or abort the
update.
Automatic
Lane Controller
Reboot
The lane controller protocol allows it to send
a reboot request to the Reader. The Reader
switches to the redundant side if the
redundant side is running and has no
switchover conditions present. If the
redundant side is not functioning, the reboot
is ignored.
User must enable Remote LC
Configuration from LC tab
on Configuration page
Web Interface
Reboot
The web interface provides a reboot button.
The Reader switches automatically to the
redundant side if the redundant side is
running and has no switchover conditions
present. If the redundant side is not
functioning, the Reader warns the operator of
potential revenue loss and allows the
operator to either continue or abort the
reboot.
Automatic
Reboot using CTM
ON/OFF switch
When the CTM ON/OFF switch is manually
switched from ON to OFF, the Reader will
automatically switch over
Automatic when the switch on
the CTM is manually set to
OFF