User's Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Maintenance Instructions
Confidential UM 360450-210: A7 Page 171 of 282
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict
confidence and will be kept confidential and used solely for the purpose intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or
used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX 10/31/2013 7:56
Kapsch TrafficCom
Result: The following screen appears.
4. Configure how multiple transactions are reported to the LC:
To send one transaction report per OBU to the LC without informing the LC of suppressed reports,
select Disabled from the Cross-Reader Reporting drop-down box.
To send on transaction report per OBU to the LC and also inform the LC of suppressed reports,
select Report Non-zero from the Cross-Reader Reporting drop-down box.
5. Configure Tag Programming (see Click the Start Logging to USB Device button.
Result: The USB Logging changes its display from Disabled to Enabled, and USB Device Status changes
to Detected to show there is an active connection between the Reader and the USB flash drive and log files
begin to get copied and updated to the USB device in realtime.
Note: You can click the Copy Log Files to USB device button if you just want to copy the present list of
log files to the USB device.
6. OBU Programming, page 56) ensuring that:
TMP and TCP are enabled
the Plaza IDs of all Readers at the plaza match
the Reader ID for each Reader is different
Note: Multiple group IDs are not supported across multiple Readers.
7. From the Channel tab on the Configuration page, ensure all channels covering one direction of traffic
have the same Group ID.
Note: The transponder timeout, set in the Group tab on the Configuration page, must be greater than the time
difference between all Reader clocks in the network.
8. Manually set the Reader clocks to within 2 seconds of the same time (refer to the Manually setting the
Reader time and date procedure on page 248).
Selecting the Voting Algorithm
Prerequisites: Connect the service laptop to the Reader configuration port to access the CTM web
interface. Refer to Connecting a service laptop to the Reader, page 40.