2. Assign an IP address to the parameter Ethernet 1 (LC 1Gbps) IP Address so that the Primary CTM is
accessible on the LC network, if necessary.
3. Assign an IP address to the parameter Ethernet 2 (IRIF 100Mbps) IP Address so that the Primary CTM is
accessible on the IR network, if necessary.
4. Assign an IP address to the parameter Reader IP Address for both primary and secondary CTMs on a given
Reader so that the Reader is accessible on the IR network, if necessary. This IP address is the same for both
CTMs in a Reader.
5. Assign an IP address to the parameter USB Adapter IP Address if a USB adapter is being used to connect a
CTM USB port to an Ethernet network.
6. Assign the gateway IP address to the parameter Default Gateway IP so that the Reader can communicate
via a gateway device such as a router, if necessary.
7. Press Enter to accept all addresses.
8. Repeat steps 1 through 7 for the secondary CTM.
Configuring an LC Ethernet network
The Reader data can also be sent to the LC via an Ethernet network.
Prerequisites: The service laptop connects to the port and the CTM web accessed. . Refer to
Connecting a service laptop to the Reader, page 40. You must have Advanced User permissions.
1. Select the Configuration link on the left side panel.