3. Select Sync to Every Superframe in the Superframe Sync Skip row.
4. Select No in the Add 2 Dummy Frames row.
5. Select JANUS from the drop-down box in the Type of Reader Synching To row.
6. Repeat these steps for all Readers in the Synchronization circuit.
7. When you are finished, press Enter to accept selections.
Synchronization between JANUS® Readers and BADGER Readers
JANUS
®
and BADGER Readers in the same synchronization network can be configured as in step 1 in the
procedure Synchronization between MPR2 Readers. However, JANUS
®
and BADGER Readers can also have the
superframe configurations shown in Table 0-3 on page 157.
Configuring Synchronization
Prerequisites: Connect the service laptop to the Reader configuration port to access the CTM web
interface. Refer to Connecting a service laptop to the Reader, page 40.
Note: Reader synchronization can also be enabled remotely by the LC if Remote LC Configuration is
enabled.
1. Select the Configuration link on the left side panel.