Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Dynamic Voting
Threshold [%]
From the Channel tab on the
Configuration page:
With Dynamic Voting Control
set to Reader, enter the voting
threshold percentage in the
Dynamic Voting Threshold
field, then, press Enter or select
a different tab.
user with
Advanced
User
permissions
DVTHSD
20
5-100
sets the voting threshold
percentage
to configure
when the
average Voting
time is adjusted.
The Voting time
will only be
updated when
the Reader
determines the
percent change
is larger than the
threshold
entered here