User's Manual

_
JANUS
®
Multi-Protocol Reader Ver. 2: Operating Instructions
Confidential UM 360450-210: A7 Page 107 of 282
© Kapsch TrafficCom Canada Inc. 2013
These drawings and specifications contain confidential and proprietary information and are the property of Kapsch TrafficCom Canada Inc. and are issued in strict confidence and will be kept confidential and used solely for the purpose
intended and for no other purpose and shall not be transmitted, reproduced, copied, and/or used as the basis for manufacture or sale of apparatus unless otherwise agreed to in writing by Kapsch TrafficCom Canada Inc.
FILE: UM 360450-210 OPERATIONS AND MAINTENANCE MANUAL.DOCX 10/31/2013 7:56
Kapsch TrafficCom
Command
How is this command
executed?
Who can
execute this
command?
Parameter
Name
Default
Parameter
Value
Parameter
Range/Options
What does this
command do?
What is the
purpose of this
command?
Group ID
From the Channel tab on the
Configuration page:
Type the Group ID in the
appropriate fields.
user with
Advanced
User
permissions
RFGPID
0
0-7
By default all channels are
in one group, such that
any cross lane reads
within the group generate
only one transaction. By
specifying different group
IDs, multiple independent
coverage zones can be
created. This is useful for
certain applications.
Used by all
protocols
LPT/FME Voting
time [ms]
From the Channel tab on the
Configuration page:
Type the voting time in the
appropriate fields.
user with
Advanced
User
permissions
LPTVTO
300
0-9999
Specify the time after the
initial entry of the
transponder into the
capture zone after which
a report is generated. This
is a trade-off between
lane assignments versus
latency. A value of 0
means no voting, subject
to the Programming
Timeout parameter.
Specific to [L]icense
[P]late [T]ags only.
Used by all