3. Select Agency or Scratchpad, as applicable. The selected data fields are displayed.
4. To view Agency or Scratchpad data from another OBU record, tap Previous to return to the OBU Acquisition
screen and repeat steps 1 through 3.
Transferring Data to the LC
Each OBU read is stored in the Portable RSE, which can store a maximum of 1000 OBU reads. To save the OBU data
long-term, it must be transferred to the LC. Once OBU data has been transferred from the Portable RSE to the LC, it is
erased from the Portable RSE.
Prerequisites: - You must have at least 10% battery life remaining or be connected to AC power.
- The Portable RSE serial port must be connected to the LC using a null modem serial cable.
- There must be OBU data stored in the Portable RSE.
- An LC that conforms to ICD 360453-702
1. From the main menu, tap LC transfer. The Transfer screen appears.
NOTE: The OBU records are automatically deleted after they have been
successfully transferred to the LC.
2. From the Transfer screen, tap Transfer to immediately begin transferring the stored OBU records to the LC. A blue
Transfer Status bar indicates the progress of the transfer.
Figure 3-8: Data transfer in progress
3. After the records have been successful transfer, a confirmation message appears: