©1999-2008 MARK IV INDUSTRIES CORP. I.V.H.S. DIVISION pg. 24 of 69
4.4 Reading and Programming IAG Tags
4.4.1 Read an IAG tag
Place the IAG tag into the foam insert in the AU drawer that is configured to accept this type of tag. (see
tag orientation photo in Appendix - Positions of tags in the AU drawer "cradle".).
Close the AU drawer. Click on "Read" button, otherwise if the Read command has been set to automatic,
then the following screen is displayed (example: a Type 2 interior FPT tag was used).
Notes: The absence of a Template File name (at bottom left) indicates that the data displayed came from the
tag just read. "Not Changed" in the selection boxes is displayed until the Supervisor makes a new selection in
order to create a new template from this one. The Vehicle Reference field value (shown as "200" in the
example above) represents the cumulative total of the first 4 field values assigned as "vehicle" data.
If the automatic Read is not set, click on the Read button. Within 1 second the tag contents are displayed
(See "Data displayed on 'Read a tag'" below).
Message "Read Failed"
The following message appears if the read command failed.
The Program command button is
highlighted in bold after the tag is
read.
"Auto write enabled" is displayed if it
has been enabled. This is a warning
for the User that opening and closing
the AU drawer will overwrite the tag
inside the drawer with the data
currently displayed.
If the "Default View Page" was set to
"Factory/Agency" then the tag data is
displayed as shown. The Supervisor
may begin modifying the displayed
template or may create a new one
from it and then save it.
Users will then be able to obtain any
one of the saved templates for use in
programming other tags.
Click on "Details" to view the error
code for the failure. A typical error
code message is depicted below.
The code shown must be
revealed to Mark IV Service Dept.
The reason for the failure detected is shown here.
Another typical reason displayed is "Drawer is open".