Datasheet

Check the value of the resistor indicated. If the value is 1K, it should be removed.
STK200’s requires no modification.
SAVING SETTINGS
The settings you have used can be saved for use again, in a FOB (.fob)
file.
To save settings, click on Save Fob button on last page, and give the file
a name.
To load a FOB settings file, click on Browse button on first screen and
select the FOB file to load.
Note:
If you try and change device with a FOB file loaded, you may get
unpredictable results. We advice you to NOT load a FOB file if you intend
to change device as the fuses could be very different.
BATTERY AND POWER SUPPLY
The Handheld Programmer uses a standard 9V PP3 battery. These are
commonly available.
The Handheld Programmer can also be powered from an external Power
Supply. The power supply should be
2.1mm barrel connector (coaxial plug), centre positive.
9V DC regulated
300 mA plus
A universal PSU or Wall Transformer is available on the Kanda shop –
Order Code PSU9V-UNI
TROUBLESHOOTING
Windows driver problems
If you get a driver error, make sure that you have run the install software
on CD and then plugged in programmer, NOT the other way round.
The driver should appear as a "USB Serial Converter" in USB section of
Device Manager. Windows should do this automatically. If it does not,
please follow this procedure.