User's Manual
2.6 Status LED Description
Status LED((Blue)
Status Description
Long light Connected to the cloud via router
Off Disconnected from router
Fast flashing Distribution mode, at which pointing pump access router can be configured by the app
Slow flashing Disconnect from the cloud
Power Indicator(( Red))
Status Description
Long light Powered on
Off No power on or a power failure
Note: X1 PRO 2 uses a red and blue two-color light, which does not need to be on when the blue status light is on or flashing.
3 Product Installation
This chapter focuses on how to install the X1 PRO 2 titration pump, as well as the precautions during installation.
Tips
This titration pump belongs to the self-absorbing pump, when the inlet and outlet drop too much, may produce siphon or reflux phenomenon.
In order to avoid siphoning and reflux, the titration pump should be placed in a reasonable position to ensure that the height difference between the
inlet and the outlet is within 0.5 meters.
The connection tube of the inlet should be as short as possible, and the drain connection tube should be suspended above the cylinder.
Please carefully check the inlet and outlet connection direction is correct, never reverse. Reference part connection section.
4 App Use
This chapter focuses on how to use the app to control the X1 PRO 2 titration pump.
4.1 Connect titration pumps to the cloud
The titration pump is powered on for the first time after the box is open, the status indicator (blue light) flashes slowly, at which point will require the use
of an app to connect the titration pump to the cloud via a wireless router, the following steps: