User's Manual
a.Working Time::The length of time that the equipment has been continuously working in this cycle;
b.Worked Volume::The total volume value of the running liquid in this cycle;
c.Time Setting:: Set the duration of a single cycle of the device, the user can enter a custom value through the keyboard
d.Running Volume setting::Set the volume of the liquid transferred in a single cycle of the device. The user can enter a custom value through the
keyboard e.Pause Time:: Set the length of time the device is suspended during the cycle;
f.Rotation::Set the rotation speed of the device during the cycle. After setting the rotation speed, the flow rate will be automatically set to the
corresponding value due to the corresponding relationship;
g.Flow Rate:: Set the flow rate when the device circulates. After setting the flow rate, the speed will be automatically set to the corresponding value due
to the corresponding relationship.
4.5 Settings page