Installation Guide
FR 5300
D
E
I
F
GB
Installation Instructions
Sanitary fitter
4
At the FR 5300 ARRONDO/ZIRKON, one
foot unit has to be installed in the middle
of the arch and another two at the arch
transitions (see Fig. ”4”).
CUTTING THE CONNECTING RODS TO SIZE
• Cut the connecting rods to size with a metal cutting saw (see
notes).
• Deburr cut edges.
With shower trays 90/90, 120/120, and
100/100 ZIRKON/ARRONDO/CORNEZZA,
cutting to size is not necessary.
With shower trays supplied by external
manufacturers, the length of the connect-
ing rods shall be measured at the shower
tray. Installation and function of the
FR 5300 are not guaranteed with shower
trays supplied by external manufacturers.
S = Side length of this Kaldewei shower tray (A)
L = Length of the connecting rod cut to size
R = Radius 50 cm with shower tray ZIRKON/
radius 55 cm with shower tray ARRONDO
Note I: Mount the central foot units in the
centre, as far as possible.
POSITION OF THE FOOT UNITS
1 = Size up to 120 cm x 120 cm (8 foot units)
2 = Size from 140 cm x 70 cm to 180 cm x
100 cm (10 foot units)
3 = Size 150 cm x 150 cm (12 foot units)
4 = Size 100 cm x 100 cm ARRONDO/ZIRKON
(8 foot units)
5 = Size 100 cm x 100 cm CORNEZZA (8 foot
units)
PREPARATION OF THE SHOWER TRAY FOOT FRAME
• Screw in sliding blocks (A) into the section of the connecting
rods (B) and tighten the hexagon socket screw (C) hand-tight by
means of the multi-purpose tool (see note I).
• Slide-in fastening plates (D) into the section of the connecting
rods (B) and fasten corner connection (E) by means of hexagon
socket screws (F).
L = S - 10 cm
L = S - 10 cm
L = S - 10 cm
L = S - 10 cm
L = S - 7 cm
L = S - 7 cm
L = S - 10 cm
L = S - 10 cm
R
90 x 90
90 x 90
90 x 90
L = S - 10 cm
L = S - 10 cm
36,1 cm
56 cm
36,1 cm
A
A
SW4
B
A
C
D
B
E
F
1 2
3
4
5