Installation Guide

FR 5300
D
E
I
F
GB
Installation Instructions
Sanitary fitter
8
PREPARING THE SHOWER TRAY
For shower trays with not centrally ar-
ranged discharge Kaldewei recommends
the use of the central supporting system
MAS 5305 (for more information see
www.kaldewei.com). In this case central
supporting with 2-component PUR foam
is not required.
With mounting system frames larger than
90 cm, it is imperative to support the cen
-
tre of the shower tray (at least 400 cm
2
)
by means of two-component PUR foam.
Tip: Use the end strips of the cardboard
box to fabricate an enclosure (A or B) for
central support. The height corresponds
to the height of the frame (D) less the
depth of the shower tray (see transport
box).
For shower trays larger than 90 cm
A= round, dia. 22 cm
B= square, 20 cm x 20 cm
For shower trays larger than 120 cm/
Shower trays with central drain
A= round, dia. 18 cm (2x)
B= square, 15 cm x 15 cm (2x)
To allow the shower tray to be exchanged
later on without any problems, fix large
pieces of plastic foil (C, not included in
the scope of supply) to the floor side with
adhesive tape. The plastic foil prevents
the PUR foam used for supporting the
centre from sticking to the shower tray.
Note I: The connection of the shower tray
to the local equipotential bonding strip
must be carried out by an authorized
electrical fitter.
Before fixing the shower tray in the foot
frame, the position of the fabrication strap
shall be checked. The fabrication strap,
the glued-on felt or the put-on protective
sleeve may not disturb the installation of
the shower tray.
Unpack shower tray carefully, checking the surface for damage.
Place upper side of the shower tray on the clean transport box.
Prepare earthing cable of sufficient length for connection to the
local equipotential bonding strip (see note I).
C
A
B
MAS 5305