Installation Guide

FR 5300
D
E
I
F
GB
Installation Instructions
Sanitary fitter
7
ALIGNING THE SHOWER TRAY FOOT FRAME
Note I: Set up the foot frame in exactly
horizontal position by means of a spirit
level to ensure a reliable water drainage.
Note II: Care should be taken that the
central foot units do not lift up the foot
units arranged at the corners and that the
foot units all stand firmly on the ground
with the sound isolating elements.
If the walls adjoining the foot frame are
not angular, the supervisor has to be in
-
formed and remedial action to be taken
(see DIN 18 202 Tolerances in building
construction - Table 2 Angle tolerances.
“The walls must not exceed the tolerance
by more than 6 mm over a length of 1 m“).
Adjust the required height by means of the four foot units (A) at
the corners of the foot frame by using the multi-purpose tool (see
note I).
Adjust the central foot units (B) such that they stand firmly on the
ground and serve as a support of the foot frame (see note II).
After the alignment of the foot frame, secure the foot units
against displacing by means of the hexagon nuts (if available) by
making use of the multi-purpose tool.
4x
5x
5x
17 mm
10 mm
20 mm
A
B