Installation Guide

FR 5300
D
E
I
F
GB
Installation Instructions
Sanitary fitter
4
At the FR 5300 ARRONDO/ZIRKON, one
foot unit has to be installed in the middle
of the arch and another two at the arch
transitions (see Fig. ”4”).
CUTTING THE CONNECTING RODS TO SIZE
Cut the connecting rods to size with a metal cutting saw (see
notes).
Deburr cut edges.
With shower trays 90/90, 120/120, and
100/100 ZIRKON/ARRONDO/CORNEZZA,
cutting to size is not necessary.
With shower trays supplied by external
manufacturers, the length of the connect-
ing rods shall be measured at the shower
tray. Installation and function of the
FR 5300 are not guaranteed with shower
trays supplied by external manufacturers.
S = Side length of this Kaldewei shower tray (A)
L = Length of the connecting rod cut to size
R = Radius 50 cm with shower tray ZIRKON/
radius 55 cm with shower tray ARRONDO
Note I: Mount the central foot units in the
centre, as far as possible.
POSITION OF THE FOOT UNITS
1 = Size up to 120 cm x 120 cm (8 foot units)
2 = Size from 140 cm x 70 cm to 180 cm x
100 cm (10 foot units)
3 = Size 150 cm x 150 cm (12 foot units)
4 = Size 100 cm x 100 cm ARRONDO/ZIRKON
(8 foot units)
5 = Size 100 cm x 100 cm CORNEZZA (8 foot
units)
PREPARATION OF THE SHOWER TRAY FOOT FRAME
Screw in sliding blocks (A) into the section of the connecting
rods (B) and tighten the hexagon socket screw (C) hand-tight by
means of the multi-purpose tool (see note I).
Slide-in fastening plates (D) into the section of the connecting
rods (B) and fasten corner connection (E) by means of hexagon
socket screws (F).
L = S - 10 cm
L = S - 10 cm
L = S - 10 cm
L = S - 10 cm
L = S - 7 cm
L = S - 7 cm
L = S - 10 cm
L = S - 10 cm
R
90 x 90
90 x 90
90 x 90
L = S - 10 cm
L = S - 10 cm
36,1 cm
56 cm
36,1 cm
A
A
SW4
B
A
C
D
B
E
F
1 2
3
4
5