Use and Care Manual
Hose / Regulator 
connection 
Regulator / Cylinder 
connection 
Page 11 of  
16
LEAK CHECK
1.
NEVER USE A LIGHTER/FLAME TO CHECK FOR GAS LEAKS.
2.
Make 2-3 oz. of leak check solution (one part liquid dishwashing
detergent and three parts water).
3.
Apply several drops of solution where hose attaches to regulator.
4.
Apply several drops of solution where regulator connects to cylinder.
5.
Make sure all fire pit and light valves are OFF. And turn cylinder valve ON
1).
Turn cylinder valve OFF.
If leak is at hose/regulator connection: tighten connection and perform 
another leak test. If bubbles continue appearing, the hose should be 
returned to the place of purchase.
2
).
  If leak is at regulator/cylinder valve connection: disconnect, reconnect, 
and perform another leak check. If you continue to see bubbles after 
several attempts, cylinder valve is defective and should be returned to 
cylinder’s place of purchase.
Operation
If
 bubbles appear at any connection, there is a leak.
If NO bubbles appear at any connection, the connections are secure. 
NOTE: Whenever gas connections are loosened or removed, you must 
perform a complete leak test. Complete installation. 