Specification Sheet

E-Plex
®
11
E-Plex
®
5000 Series
Software Specifications
Communication
Locks are programmed and audits downloaded using a handheld PDA (personal digital assistant)
Communicates through infrared data transfer – requiring no dedicated cables or equipment – just point your PDA at the lock’s
transfer window
Visual confirmations provided during data transfers
PDA battery gauge used to quickly test lock’s battery status – just point and click
Audit
Lock records last 3,000 access events, including key override, to provide increased user accountability
Audit information is downloaded to Excel spreadsheets for increased flexibility
- Use spreadsheets for analyzing, sorting or printing data according to your needs – unlike the “canned” pre-programmed
audits found in most access control systems
Authority Levels
Five authority levels allow you to specify which users have access to various lock functions:
- Each site is assigned one Master Level and one Communications (M-Unit) Level: the remaining 99 codes can be set to
Manager, User, and Service levels
- Master and Manager levels have authority to gain access to various lock functions
-
Access User level has authority to gain access only
-
Service level has authority to gain access once, or programmed for 1 to 24 hours – for service personnel, meeting rooms,
and rental space
-
Communications (M-Unit) level has authority to program and audit without access to door
Operational Modes
Flexible operational modes accommodate security needs during the business day
- Combination (PIN) entry
- Passage – can be toggled on and off at the lock – re-lock can be set for between 1 to 24 hours
- Lockout
Customizable User Preferences
Re-lock time – adjustable on a lock-by-lock basis from 2 to 20 seconds
User code length – 4 to 8 digits
Anti-tamper
- Adjustable between 3 to 9 invalid attempts before anti-tamper feature disables lock
- Lockout set for up to 90 seconds
Compatibility
Computer and Pentium class personal computer
processor:
Memory:
128 megabytes (MB) of RAM or greater
Hard Disk: 500 MB of available hard-disk space
Drive: CD-ROM or DVD drive
Operating System: Microsoft Windows 98SE, NT SP4, 2000, XP (not supplied) – visit www.e-plexlock.com for
up-to-date listing
Microsoft Excel: Excel 97 or newer software (not supplied)
Handheld PDA: Palm Operating System 4.X or 5.X (not supplied) – visit www
.e-plexlock.com for up-to-date listing
Access Control Catalog - June 2004