Warranty

For Professional Technical Support call 1-844-242-2475 9
2. Install screen surround the foot valve, protect the foot valve
assembly from fish, trash, etc. Position the foot valve 5 feet
above bottom of well and It should also be at least 10 feet
below the water level in order to prevent the pump from
sucking air. (Fig 2)
3. Cement 1in. PVC MPT×S Male Adapter into 1 in. PVC
rigid Pipe. Install 1in.PVC TEE FPT×FPT×FPT to adapter.
One end of horizontal port install another 1in. PVC MPT×S
Male Adapter and 1in. PVC rigid Pipe. Add sections of pipes
to reach the 1in. PVC Slip ×Slip Union (optional). (Fig. 3)
2. Well To Pump Connection
1. Thread 1in. PVC MPT×S Male Adapter into pump.
Cement a short horizontal 1in. PVC rigid Pipe into adapter.
(Fig.1)
2. For pre-charged tank connection. Cement a 1in. PVC
Slip× Slip Union into a short horizontal 1in. PVC rigid Pipe.
Slopes all inlet piping slightly upward from well to the pump
to prevent trapping air.(Fig.2)
For standard tank connection. Cement 1in. ×1in. ×3/4in.
PVC S×FPT Reducer Tee Fitting into a short horizontal
1in. PVC rigid Pipe and cement another a short horizontal
1into the side of the tee fitting, then install3/4in.
MIP×1/2in.FIP Lead-Free Brass Hex Bushing Fitting to
the port of 3/4in, thread and another 1/2in. MIP×1/8in.FIP
Lead-Free Brass Hex Bushing Fitting to the bushing
fitting.