Troubleshooting Guide
    2   Sump & Pedestal Pump Troubleshooting Guide            
K2P  
K2 PUMPS CUSTOMER SERVICE, CALL 844.242.2475 
SAFETY INSTRUCTIONS 
All electrical work should be performed by a licensed electrician. 
WARNING: Risk of electrical shock. Disconnect power to the pump before servicing. Do not handle the 
pump with wet hands or when standing on a wet or damp surface. 
WARNING: Risk of fire or explosion. Pump water only with this pump. Do not use this pump in the presence 
of flammable or explosive vapors. 
CAUTION: Motors run hot. Do not touch the motor housing during operation.  
Read and follow all safety instructions on the pump label and in the owner’s manual for your pump. 
Problem 1: Pump will not start or run  
Possible Causes  Corrective Action 
1. The circuit breaker has tripped 
1. Reset the circuit breaker by switching the breaker to 
the "ON" position. The pump must be plugged into an 
outlet that is on a dedicated 15 Amp circuit breaker.  
2. The plug is disconnected 
2. Make sure the plug is securely connected 
3. The plug is corroded 
3. Clean the prongs of the plug 
4. Water level in sump basin is not high enough to 
activate the float switch 
4. When the water level reaches the right height, the 
pump will start 
5. The float switch is stuck 
5. Remove any obstructions and make sure the float 
switch can move freely 
6. Submersible sump only - the float switch failed* 
6. Replace the float switch* 
7. Debris is caught in the impeller, pump inlet or 
discharge pipe 
7. Remove the debris. Refer to the "Care and Cleaning" 
instructions in your manual 
8. Thermal overload due to pump overheating 
8. Unplug the pump and allow it to cool for at least 30 
minutes, plug the pump in again. 
9. Pump overheats regularly 
9. Sump pumps are designed to remove water from a 
sump basin. These pumps should not be used in 
continuous applications, e.g. pumping water in a pond 
or waterfall. 
10. The motor has failed 
10. Replace the pump 
11. Low supply voltage 
11. Consult a professional electrician 
12. Pedestal pump only - the float ball won't float 
because it is stuck or positioned incorrectly 
12. Remove and reposition the pump so that nothing is 
obstructing the float switch. Contact Customer Service 
if you need further assistance. 
* Pedestal Sump pumps do not have replacement switches. If the switch fails, replace the pump. 