Model: PPV10001SPK PPV15001SPK OWNER’S MANUAL VARIABLE SPEED POOL PUMP Questions, problems, missing parts? Before returning to the store call K2 Customer Service 8 a.m. - 6 p.m., EST, Monday-Friday 1-844-242-2475 www.K2pumps.com Copyright © 2021, GP Enterprises Co., Ltd. K2Man-32 (Rev.
PERFORMANCE SKU HP PPV10001SPK PPV15001SPK 1 1-1/2 RPM GPM of Water @ Total Feet of Lift Max. Lift 0 ft. 10 ft. 20 ft. 30 ft. 40 ft. 50 ft. 3500 72.0 65.0 56.0 44.0 25.0 / 48 ft. 2000 39.0 20.0 / / / / 16 ft. 1200 22.0 / / / / / 7 ft. 3500 95.0 88.0 80.0 70.0 56.0 40.0 65 ft. 2000 50.0 32.0 7.0 / / / 22 ft. 1200 30.0 / / / / / 8 ft. SAFETY INSTRUCTIONS 1.
17. CAUTION: Use a supplier recommended primer to ensure glued joints are secure. Many local codes require primer with a purple tracer to verify primer use. 18. CAUTION: Consider climatic conditions when applying adhesives. Atmospheric conditions with high humidity will make the adhesive action of certain glues less effective. Follow the manufacturer's instructions. 19. CAUTION: This pump should be installed and serviced only by a qualified pool service professional.
PACKAGE CONTENTS Part A B C D Description Pump Union Nut Union Adapter O-ring QTY 1 2 2 2 MATERIALS REQUIRED (NOT INCLUDED) Additional items needed QTY Teflon tape As needed Rigid pipe As needed Ball Valve As needed Union As needed Elbow As needed Adapter 2 Tee As needed PVC cement 1 IAPMO Certified Anti-entrapment Cover As needed SPECIFICATIONS Power supply 230V, 60 HZ., 15 Amp Circuit Liquid temp. range 32 to 100°F (0- 38°C) Discharge size 1 -1/2 in.
PUMP PLUMBING Suction pipe should be as large as or larger than discharge pipe. Avoid using a suction pipe smaller than the pump connection. The pump is designed to accept 1-1/2 in. suction piping. 1. Keep the piping as straight and short as possible, and of suitable size. 2. Avoid connecting an elbow directly into the pump inlet. A length of straight pipe will allow proper entry of the water to the pump. 3. Slope horizontally, and run upward to the pump to prevent trapping air. 4.
Suction inlets must be designed so that water is drawn simultaneously. A vacuum relief device can be installed in line leading to the pump suction. All suction outlet covers must conform to ASME/ANSI A112.19.18M; or must be a minimum 18 x 23 grate or larger; or must have an approved channel drain system. Skimmers are exempted. All pool and spa single or multiple outlet circulation systems shall be equipped with an atmospheric vacuum relief system. The system must be ASME/ANSI A112.19.17 Rated.
Connect a No. 8 AWG solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of the swimming pool, spa, or hot tub and to all electrical equipment, metal piping or conduit within 5 feet of the inside walls of swimming pool, spa, or hot tub. Follow all national and local wiring codes. If unsure of the code requirements, consult a professional electrician. Pump must be permanently connected to circuit.
OPERATION Avoid running pump dry. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes. 3. RELEASE ALL PRESSURE from pump and piping system. 4. If pump is being pressure tested, be sure pressure has been released before removing trap cover. WARNING: Do not block pump suction. To do so with body may cause severe or fatal injury. Small children using pool must ALWAYS have close adult supervision.
4. Clean and inspect lid O-ring; then reinstall the ring and cover assembly. 5. Prime the pump (see priming instructions). Draining the Pump A. Pump down water level below all inlets to the pool. WARNING: To avoid dangerous or fatal electrical shock hazard, turn OFF power to the motor before draining pump. B. Remove the trap cover. C. Drain the basket housing and pump housing through the drain plugs D. Clean the pump and basket, then replace cover assembly. E. Be sure motor is kept dry and covered.
1. Pump operation mode Power on default manual mode Press AUTO to start manually Put AUTO manual mode on again and stop Press AUTO again Press AUTO again to close the auto mode In the automatic mode,4 working periods can be set every day, and the rotation speed of the four working periods can be set to different speeds, among which the rotation speed is adjustable 600RPM~3500RPM.
2. Set pump parameters Long press the set key for 3 seconds Set time mode Set the time and speed of time period 1 Set the time and speed of time period 2 Set the time and speed of time period 3 Set the time and speed of time period 4 To exit the setting mode, do not press the button for 10 seconds 3.Set time Long press for more than 3 seconds to enter the setting mode and enter the setting time state. The 12 of start flashing, you can go through enter the mode of setting minutes.
, also can adjust speed by and ,when press ,automatic recording speed and enter the set period 2,and so on. The first time period can be set to a maximum of 0:00-23:59. The second time period can be set as the maximum time period (stop time of the first time period-23:59). Time periods 3 and 4 are turned off by default and can be turned on by either or .When the settings are complete, wait 10 seconds for the system to automatically save the settings.
Pump Disassembly/Removing Old Seal Before disassembly, disconnect power to pump motor. Be sure gate valves on suction and return piping are closed. Release all pressure by opening all vents. 1. Drain pump by removing drain plugs on bottom of pump body and trap body. 2. Be sure there is no pressure in trap body; remove cover (unscrew by turning counterclockwise). 3. Remove eight nuts, lock washers and flat washers holding seal plate to pump body. Pull seal plate and motor away from pump body.
TROUBLESHOOTING Read and understand safety and operating instructions in this manual before doing any work on pump! Only qualified personnel should electrically test the pump motor! FAILURE TO PUMP; REDUCED CAPACITY OR DISCHARGE PRESSURE. Problem Possible Cause The pump is not priming. There are leaks in the suction piping. The suction inlet is above water level. The pump does not pump water. The vertical distance of the pump is too high to water lever. The pump is clogged.
WARRANTY K2 Pumps Limited Warranty WHAT THIS WARRANTY COVERS This Limited Warranty is effective September 1, 2020 and replaces all undated warranties dated prior to September 1, 2020. K2 Pumps (K2) warrants to the original consumer purchaser (You) that its products are free from original defects in material and workmanship for at least one year (warranty varies depending on model; see box or K2 website for specific warranty information) from the date of purchase (the Warranty Period).
Modelo: PPV10001SPK PPV15001SPK MANUAL DEL PROPIETARIO BOMBA DE VELOCIDAD VARIABLE PARA PISCINAS ¿Preguntas, problemas, piezas faltantes? Antes de regresar a la tienda, comuníquese con el servicio de atención al cliente de K2 de 8 a.m. a 6 p.m., hora del este (EST), de lunes a viernes 1-844-242-2475 www.K2pumps.
RENDIMIENTO GPM de agua a pies totales de elevación (alta velocidad) Modelo PPV10001SPK PPV15001SPK HP 1 1-1/2 RPM 50 f pies. Elevación máx. 25.0 / 48 ft. / / / 16 ft. / / / / 7 ft. 88.0 80.0 70.0 56.0 40.0 65 ft. 50.0 32.0 7.0 / / / 22 ft. 30.0 / / / / / 8 ft. 0 pies 10 pies 20 pies 30 pies 3500 72.0 65.0 56.0 44.0 2000 39.0 20.0 / 1200 22.0 / 3500 95.0 2000 1200 40 pies INSTRUCCIONES DE SEGURIDAD 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13.
18. PRECAUCIÓN: Tenga en cuenta las condiciones climáticas al aplicar los adhesivos. Las condiciones atmosféricas con alta humedad harán que la acción adhesiva de ciertos pegamentos sea menos eficaz. Siga las instrucciones del fabricante. 19. PRECAUCIÓN: Esta bomba debe ser instalada y reparada solo por un profesional calificado de servicio de piscinas.
CONTENIDO DEL PAQUETE Pieza A B C D Descripción Bomba Tuerca de unión Adaptador de unión Junta tórica Cant. 1 2 2 2 MATERIALES NECESARIOS (NO INCLUIDOS Elementos adicionales necesarios Cant.
TUBERÍAS DE LA BOMBA La tubería de succión debe ser tan grande o más grande que la tubería de descarga. Evite usar una tubería de succión más pequeña que la conexión de la bomba. La bomba está diseñada para aceptar tuberías de succión de 1-1/2 pulgadas. 1. Mantenga la tubería lo más recta y corta posible, y del tamaño adecuado. 2. Evite conectar un codo directamente a la entrada de la bomba. Un tramo de tubería recta permitirá la entrada adecuada de agua a la bomba. 3.
Las entradas de succión deben diseñarse de modo que el agua se extraiga simultáneamente. Se puede instalar un dispositivo de alivio de vacío en la tubería que conduzca a la succión de la bomba. Todas las cubiertas de las salidas de succión deben cumplir con las normas ASME/ANSI A112.19.18M, deben tener una rejilla mínima de 18 x 23 o más o deben tener un sistema de drenaje de canal apropiado. Los skimmers están exentos.
Conecte un cable de unión de cobre sólido número 8 AWG al conector del cable de presión provisto en la carcasa del motor y a todas las partes metálicas de la piscina, hidromasaje o jacuzzi y a todos los equipos eléctricos, tuberías o conductos metálicos dentro de los 5 pies de la parte interior de las paredes de la piscina, hidromasaje o jacuzzi. Siga todos los códigos de cableado nacionales y locales. Si no está seguro de los requisitos del código, consulte a un electricista profesional.
OPERACIÓN ADVERTENCIA: riesgo de explosión. Antes de quitar la cubierta de la trampa: AVISO: NUNCA haga funcionar la bomba en seco. Hacer funcionar la bomba en seco puede dañar los sellos y causar fugas e inundaciones. Llene la bomba con agua antes de arrancar el motor. 1. Detenga la bomba antes de proceder. 2. Cierre las válvulas de compuerta en los tubos de succión y descarga. 3. Libere toda la presión de la bomba y el sistema de tuberías. 4.
2. Retire el conjunto de anillo y cubierta girándolo en sentido contrario a las agujas del reloj. Si es necesario, golpee suavemente las manijas con un mazo de goma. 3. Retire la cesta y límpiela. Inspeccione los agujeros para ver si hay obstrucciones. Limpie la cesta con agua y colóquela en la trampa. Verifique que la cesta esté orientada correctamente en la carcasa de la bomba. 4. Limpie e inspeccione la junta tórica de la tapa y luego vuelva a instalar el conjunto de anillo y cubierta. 5.
1.
2. Configuración de los parámetros de la bomba Mantener presionada la tecla de configuración durante 3 segundos Configurar el modo de tiempo Configurar la hora y la velocidad del período 1 Configurar la hora y la velocidad del período 2 Configurar la hora y la velocidad del período 3 Configurar la hora y la velocidad del período 4 Para salir del modo de configuración, no presione el botón durante 10 segundos 3.Configuración de la hora Mantenga presionado el botón de la hora. Cuando el 12 de horas.
de los botones o ajustar la velocidad con y , se debe presionar para confirmar la velocidad de grabación automática e ingresar el período establecido 2, y así sucesivamente. El primer período se puede establecer en un máximo de 0:00-23:59. El segundo período se puede establecer como el período máximo (hora de detención del primer período: 23:59). Los períodos 3 y 4 están desactivados de forma predeterminada y se pueden activar con los botones o .
Desmontaje de la bomba/remoción del sello antiguo Antes del desmontaje, desconecte la energía del motor de la bomba. Asegúrese de que las válvulas de compuerta en las tuberías de succión y retorno estén cerradas. Abra todas las rejillas de ventilación para liberar la totalidad de la presión. 1. Quite los tapones de drenaje en la parte inferior del cuerpo de la bomba y el cuerpo de la trampa para drenar la bomba. 2.
SOLUCIÓN DE PROBLEMAS Lea y comprenda las instrucciones de seguridad y funcionamiento de este manual antes de realizar cualquier trabajo en la bomba. ADVERTENCIA: riesgo de descarga eléctrica. Puede dar un choque eléctrico, quemar o matar. Desconecte la energía antes de trabajar en la bomba o el motor. Lea y comprenda las instrucciones de seguridad y funcionamiento de este manual antes de realizar trabajos en la bomba.
GARANTIA K2 Pumps Garantía Limitada LO QUE CUBRE ESTA GARANTÍA Esta Garantía Limitada entra en vigor a partir del 1 de septiembre de 2020 y reemplaza todas las garantías sin fecha y aquellas con fechas anteriores al 1 de septiembre de 2020.