Instructions / Assembly
For Professional Technical Support call 1-844-242-2475 5
PACKAGE CONTENTS
Part
Description
QTY
A
Pump
1
B
Union Nut
2
C
Union Adapter
2
D
O-ring
2
MATERIALS REQUIRED (NOT INCLUDED)
Additional items needed
QTY
Teflon tape As needed
Rigid pipe
As needed
Ball valve As needed
Union
As needed
Elbow As needed
Adapter 2
Tee
As needed
PVC cement 1
IAPMO Certified Anti-entrapment Cover
As needed
SPECIFICATIONS
Power supply
230V, 60 Hz., 15 Amp Circuit
Liquid temp. range
32 to 100°F (0- 38°C)
Discharge size 1-1/2 in. NPT
INSTALLATION
NOTICE: For quick disconnect pipe connections, use the 1-1/2 in. Slip Half Union Kit included with the pump. Only
qualified, licensed personnel should install pump and wiring.
Pump mount must:
Be located away from corrosive or flammable liquids.
Have enough ventilation to maintain air temperature at less than the maximum ambient temperature rating (Max.
Amb.) listed on the motor model plate. If this pump is installed in an enclosure/pump house, the enclosure must
have adequate ventilation and air circulation to keep the temperature in the enclosure at or below the motor’s
rated ambient temperature whenever the pump is running.
Be solid - Level - Rigid - Vibration free. (to reduce vibration and pipe stress, bolt pump to mount.)
Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10 ft.
(3 m).