Troubleshooting Guide
2 Sprinkler Pump Troubleshooting Guide
K2Pumps.com
K2 PUMPS CUSTOMER SERVICE, CALL 844.242.2475
SAFETY INSTRUCTIONS
All electrical work should be performed by a licensed electrician.
WARNING: Risk of electrical shock. Disconnect power before working on pump, motor, pressure
switch or wiring.
CAUTION: Motors run hot. Do not touch an operating motor. Before handling the pump, disconnect power
and allow the motor to cool down for 20 minutes.
Read and follow all safety instructions on the pump label and in the owner’s manual for your pump.
Problem 1: Motor will not run
Possible Causes
Corrective Action
1. Disconnect switch is off.
1. Be sure switch is on.
2. Fuse is blown or circuit breaker tripped.
2. Replace fuse.
3. Wires at motor are loose, disconnected or
wired incorrectly.
3. Refer to wiring instructions. Check and tighten all wiring.
WAENING: Capacitor voltage MAY be hazardous. To discharge
capacitor, touch short capacitor terminals with an insulated
screwdriver. BE SURE to hold handle of screwdriver while making
contact with capacitor terminals.
4. Defective Motor.
4. Replace motor.
5. Voltage selector switch not properly set.
5. Disconnect power, set voltage selector switch (Figure 5) to
match line voltage. (See electrical connections page 3.)
6. Low line voltage.
6. Contact an electrician.