Material Safety Data Sheet

Material Safety Data Sheet
Document: K2Q-6-460-0012
Revision: 1
Page 2 of 5
Section 4 First Aid Measures
Skin Contact: Wash affected area with lukewarm water for at least 30 minutes. If irritation or pain
persists, seek medical attention.
Eye Contact: Wash affected eye with lukewarm water for at least 30 minutes. Rinse with saline solution
if possible. Seek medical attention.
Inhalation: Move victim to fresh air and remove source of contamination from area. Seek medical
attention.
Caution: In all cases if irritation persists, seek medical assistance at once.
Section 5 - Fire Fighting Measures
Extinguishing Media: Water, carbon dioxide, dry chemical powder and foam are most effective means
to extinguish a battery fire
Fire Fighting Procedure: Put on fully protective gear, including self-contained breathing apparatus,
goggles, fireproofing jacket and gloves.
Unusual Fire and Explosion Hazards: Exposing battery pack or cell to excessive heat, fire or over voltage
condition may cause a leak, fire, hazardous vapors and hazardous decomposition products. Damaged or
opened cells or batteries can result in rapid heating and the release of flammable vapors.
Section 6 - Accidental Release Measures
The material contained within the batteries or cells is only expelled under abusive conditions. Use a
shovel and cover battery with sand or vermiculite, place in an approved container and dispose in
accordance with section 13.
Section 7 Handling and Storage
Handling: Do not expose battery or cell to extreme temperatures or fire. Do not disassemble, crush or
puncture battery.
Storage: Insulate positive and negative terminals to avoid short circuit. Store in a cool and well
ventilated area and avoid direct sunlight. Elevated temperatures can result in reduced battery life.
Section 8 Exposure Controls and Personal Protection
Respiratory Protection: Not necessary under normal use. In case of battery or cell rupture, use a self
contained full face respiratory mask.
Eye Protection: Not necessary under normal use. Wear safety goggles if handling a ruptured or leaking
cell or battery pack.
Hand Protection: Not necessary under normal use. Wear Viton rubber gloves if handling a ruptured or
leaking cell or battery pack.
Skin Protection: Not necessary under normal use. Wear rubber apron and Viton rubber gloves if
handling a ruptured or leaking cell or battery pack.
Section 9 Physical and Chemical Properties