M10936
P
N7150 User Manual
UM
10936 All information provided in this document is subject to legal disclaimers.
U
ser manual
CO
MPANY PUBLIC
Rev. 2.06 November 2020
348120
87 of 127
Na
me & Rights
D
escription
Ex
t. Tag
L
en.
D
efault
Value
T
O_BEFORE_STDBY_
CFG
RW in E²PROM
Timeout used to wait after last DH-NFCEE communication
before going into standby (from 0 to 65.536s in steps of 1ms).
Applies only when the discovery is stopped and standby mode
is activated by SET_PWR_MODE_CMD.
Pay attention that the parameter value is defined in little
endian (LSB first).
0xA0 0x09 2 0x03E8
(1s)
PAD_SLEW_RATE_CFG
RW in E²PROM
Parameter used to configure the slew rate of the pads, on a
per pad basis:
Bit Mask Description
b7 b6 b5 b4 b3 b2 b1 b0
X CL
K_REQ
X I
RQ
0 0 0 0 0 0 RFU
F
or each of the pads, '1' => fast slew rate, '0' => slow slew
rate.
0xA0 0x0A 1 0x00
RF
_TRANSITION_CFG
RW in E²PROM
TLV parameter to configure the RF transitions: see chapter
10.3