User manual

Deutsch 3
Repeat this cleaning process if neces-
sary or with severe contamination!
Î After cleaning, switch off the high pres-
sure cleaner.
Î Remove the dirt from the sieve area.
Î Remove the sieve.
Illustrations on fold-out page!
Illustration
Illustration
Î The pipe cleaning kit is ideally suited for
the cleaning of pipes and drains with a
diameter of at least 40 mm (1.5") and a
radius of at least 70 mm (2.75").
Note: If you have already worked with the
roof gutter set, you must first pull the high
pressure hose with its adapter out of the
cleaning sled:
Î Loosen the clip and pull the high pres-
sure hose off.
Î Unscrew the adapter from the high
pressure hose (12 mm open end
wrench).
Illustration
Î Screw the high pressure nozzle for pipe
cleaning onto the high pressure hose
(using a 13 mm open end wrench).
Î Operate the high pressure cleaner as
instructed in the operating instructions.
Illustration
Î Press the coupling of the tube cleaning
hose into the bayonet connection of the
high-pressure gun.
Î Turn the coupling part by 90° until it
locks into place.
Illustration
Î Insert the pipe cleaning hose into the
pipe to be cleaned up to the red mark.
see Figure 11
Î Turn on the high-pressure cleaner.
Î Press the lever of the high-pressure
gun and manually guide the pipe clean-
ing hose with the automatic advance.
Note: The yellow marking clip is used as a
guide and can be clipped onto the pipe
cleaning hose. You can use this to see how
far the pipe cleaning hose has been ad-
vanced.
Î If the high pressure hose for pipe clean-
ing meets an obstruction, repeatedly
press and release the high pressure
gun lever.
Repeat this cleaning process if neces-
sary or with severe contamination!
Î After cleaning, switch off the high pres-
sure cleaner.
Pipe cleaning set
Description of the Appliance
2 High pressure hose (pipe cleaning
hose)
3 Red mark
9 High pressure nozzle for pipe cleaning
10 Marking clip, yellow
Preparing the Appliance
Operations
10 EN