Specifications

5
CH 3 Gobo Rotation
Value# Function
0 STOP
1-99 CW
100-155 STOP
156-255 CCW
In DMX mode and SLAVE mode, the lamp will be blacked out automatically if there is no DMX signal
input.
SERVICE:
There are no user serviceable parts inside except the lamp. Refer all service to a qualied technician.
Lamp replacement:
1. Disconnect the xture from AC power and allow it to cool for 15 minutes.
2. Loosen the access screws and lift the cover.
3. Remove the base of the old lamp from the socket.
4. Install the new lamp: ELC 24 V/250 W GX5.3 halogen.
Push the lamp base pins fully, but gently, into the socket.
To ensure maximum lamp life, avoid touching the lamp with bare hands.
Replace the main fuse:
1. Unplug the mains cable from the output socket.
2. Open the fuse holder and replace the fuse with one of the same type. The fuse rating is listed on
the rating label.
TROUBLESHOOTING:
Problem Probable cause Solution
One or more xtures are
completely dead.
No power to the xture.
Make sure that cables are
plugged in and power is switched
on.
Main fuse blown. Replace fuse.
Fixture is working correctly but
no light output.
Broken or worn out lamp. Install new lamp.
Fixtures reset correctly but
all respond erratically or not
at all to controller.
Controller not connected. Connect controller.
XLR pin-out of controller does
not match pin-out of rst xture
on link (polarity is reversed).
Install a phase-reversing cable
between controller and rst
xture on link.
Fixtures reset correctly but
some respond erratically or
not at all to controller.
Bad data link connection.
Inspect connections and cables.
Correct poor connections. Repair
or replace damaged cables.
Data link not terminated with
120 Ohm termination plug.
Insert termination plug in output
of last xture on link.
Incorrect xture addressing. Check DMX addresses.
One of the xtures is
transmitting as a master.
Check all xture settings.